X-Git-Url: http://shamusworld.gotdns.org/cgi-bin/gitweb.cgi?a=blobdiff_plain;ds=inline;f=include%2Fmonitor-section.html;h=af5976ada6bbf5d6f13dc15ff03ac2aaaaf9713e;hb=7d0008ace8d95c5b31cb18c862b9322a2d28ed6a;hp=7cf3ed276515ac07f30dcf7f1cfda74aa4d96aca;hpb=1bc084d882bf5792634c5fd08c35eff78de26b02;p=ardour-manual diff --git a/include/monitor-section.html b/include/monitor-section.html index 7cf3ed2..af5976a 100644 --- a/include/monitor-section.html +++ b/include/monitor-section.html @@ -7,14 +7,16 @@
- The Monitor section is an optional feature that provides Control Room/Monitor Speaker outputs. It can be activated for the current session in the - + The Monitor section is an optional feature that provides Control Room/Monitor Speaker outputs. + It can be activated for the current session in the + Session > Properties window by enabling the Use monitor section in this session option in the - Monitoring tab. By default the Monitor Section is fed with audio from the Master Bus, but depending on solo mode and other functions such as Auditioning, other audio sources may be temporarily heard instead. + Monitoring tab. By default the Monitor Section is fed with audio from the Master Bus, + but depending on solo mode and other functions such as Auditioning, other audio sources may be temporarily heard instead.
- The Monitor section appears on the right hand side of the Mixer, and comprises: + When you click the "Mon" button on the Master bus, the Monitor section appears on the right hand side. It comprises:
- The Status indicators, two of which also appear in the Transport tool bar, flash to indicate when that function is in operation: + The Status indicators, two of which also appear in the Transport tool bar, + flash to indicate when that function is in operation:
- The SiP, PFL and AFL controls inter-cancel with each other and select the desired Solo mode. Excl. Solo and Solo Mute then modify the modes behaviour. See Muting and Soloing. The current mode is indicated by the illuminated 'LED' on the button. + The SiP, PFL and AFL controls inter-cancel with each other and select the desired Solo mode. Excl. + Solo and Solo Mute then modify the modes behaviour. See Muting and Soloing. + The current mode is indicated by the illuminated 'LED' on the button.
SiP | This selects Solo In Place as the current solo mode and cancels the previous mode. |
---|
Solo Boost | This is the level that will be added to the current main monitor level when a track or bus is soloed, providing a convenient boost in level for the isolated signal. The rotary control has a range of 0dB to +10dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience. |
---|---|
SiP Cut | Only relevant to Solo in Place mode. This sets the level that all muted tracks or busses will be muted by. By default it is -&infinity; i.e. the non soloed tracks are totally inaudible. The level can be raised to make the other tracks audible, though dimmed. This is also sometimes referred to Solo in Front. The rotary control has a range of -inf to +0dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience. |
Solo Boost | This is the level that will be added to the current main monitor + level when a track or bus is soloed, providing a convenient boost in level for the isolated signal. + The rotary control has a range of 0dB to +10dB and can be set at any point between these two values. + A drop down menu with pre-defined values is also provided for convenience. |
SiP Cut | Only relevant to Solo in Place mode. This sets the level that all muted tracks + or busses will be muted by. By default it is −∞ i.e. the non soloed tracks are totally inaudible. + The level can be raised to make the other tracks audible, though dimmed. This is also sometimes referred + to Solo in Front. The rotary control has a range of −∞ to +0dB and can be set at any point + between these two values. A drop down menu with pre-defined values is also provided for convenience. |
- The Dim level control sets the amount by which the monitoring will be reduced when a Dim button is engaged. The rotary control has a range of -20dB to 0dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience. + The Dim level control sets the amount by which the monitoring will be reduced when a Dim button is engaged. + The rotary control has a range of -20dB to 0dB and can be set at any point between these two values. + A drop down menu with pre-defined values is also provided for convenience.
- Each of the individual paths through the Monitor Section, (e.g. L and R for stereo), can be controlled individually. Four functions are available: + Each of the individual paths through the Monitor Section, (e.g. L and R + for stereo), can be controlled individually. Four functions are available:
Mute | Mutes the selected path(s) |
---|