   at a single meter.
 </p>
 <p>
-  Yet, if you want to work in or with the broadcast industry, it is
+  Yet, in order to work in or with the broadcast industry, it is
   usually unavoidable to use meters.
 </p>
 <p>
@@ -19,7 +19,7 @@
   <li>When tracking, meters are used to ensure that the input
   signal does not <dfn>overload</dfn> and maintains reasonable
   <dfn>headroom</dfn>.</li>
-  <li>Meters offer a <dfn>quick visual indication</dfn> of a
+  <li>Meters offer a <dfn>quick visual indication</dfn> of an
   activity when working with a large number of tracks.</li>
   <li>During mixing, meters provide an rough estimate of the
   <dfn>loudness</dfn> of each track.</li>
@@ -38,7 +38,7 @@
 <ul>
   <li><a href="http://www.digido.com/how-to-make-better-recordings-part-2.html">How To Make Better Recordings in the 21st Century&mdash;An Integrated Approach to Metering, Monitoring, and Leveling Practices</a> by Bob Katz. Has a good historic overview of meters and motivates the K-meter</li>
   <li><a href="https://en.wikipedia.org/wiki/Peak_programme_meter#Table_of_characteristics">Wikipedia: Peak programme meter</a>&mdash;overview of meter types.</li>
-  <li>"Audio Metering: Measurements, Standards and Practice: Measurements, Standards and Practics", by Eddy Brixen. ISBN: 0240814673</li>
+  <li>"Audio Metering: Measurements, Standards and Practice: Measurements, Standards and Practice", by Eddy Brixen. ISBN: 0240814673</li>
   <li>"Art of Digital Audio", by John Watkinson. ISBN: 0240515870</li>
 </ul>
 
@@ -46,9 +46,9 @@
   There are different metering standards, most of which are available in Ardour. In short:
 </p>
 
-<dl>
-  <dt>Digital peak-meter</dt>
-  <dd>A <dfn>Digital Peak Meter</dfn> displays the absolute maximum signal
+<table class="dl">
+  <tr><th>Digital peak-meter</th>
+  <td>A <dfn>Digital Peak Meter</dfn> displays the absolute maximum signal
   of the raw audio PCM signal (for a given time). It is commonly used when
   tracking to make sure the recorded audio never clips. To that end, DPMs
   are always calibrated to 0&nbsp;<abbr title="DeciBel Full
   exact specifications.
   <p>
   Various conventions for DPM fall-off times and dBFS line-up level can be
-  chosen in <kbd class="menu">Edit &gt; Preferences &gt; GUI</kbd>.
+  chosen in <kbd class="menu">Edit &gt; Preferences &gt; Metering</kbd>.
   </p>
-  </dd>
+  </td></tr>
 
-  <dt>RMS meters</dt>
-  <dd>An <dfn><abbr title="Root Mean Square">RMS</abbr>-type meter</dfn>
+  <tr><th>RMS meters</th>
+  <td>An <dfn><abbr title="Root Mean Square">RMS</abbr>-type meter</dfn>
   is an averaging meter that looks at the energy in the signal. It
   provides a general indication of loudness as perceived by humans. Ardour
-  features three RMS meters, all of which offer additonal peak indication.
+  features three RMS meters, all of which offer additional peak indication.
   <ul>
     <li><dfn>K20</dfn>: A meter according to the K-system introduced by Bob
     Katz, scale aligned to -20&nbsp;dBFS, rise/fall times and color schema
     <li><dfn>K14</dfn>: Same as K20 with scale aligned to -14&nbsp;dBFS.</li>
     <li><dfn>K12</dfn>: Same as K20 with scale aligned to -12&nbsp;dBFS (since 3.5.143).</li>
     <li><dfn>Peak + RMS</dfn>: standard RMS, customizable via
-    <kbd class="menu">Edit &gt; Preferences &gt; GUI &gt; Metering</kbd></li>
+    <kbd class="menu">Edit &gt; Preferences &gt; Metering</kbd></li>
   </ul>
-  </dd>
+  </td></tr>
 
-  <dt>IEC PPMs</dt>
-  <dd><dfn><abbr title="International Electrontechnical Commission">IEC</abbr>-type
+  <tr><th>IEC PPMs</th>
+  <td><dfn><abbr title="International Electrontechnical Commission">IEC</abbr>-type
   <abbr title="Peak Programme Meters">PPM</abbr>s</dfn> are a mix between DPMs and
   RMS meters, created mainly for the purpose of
   interoperability. Many national and institutional varieties exist (<abbr
   outside the context of broadcast.
   </p>
   <p>
-  Their specification is very exact, and consquently, there are no
+  Their specification is very exact, and consequently, there are no
   customizable parameters.
   </p>
-  </dd>
+  </td></tr>
 
-  <dt>VU meters</dt>
-  <dd><dfn><abbr title="Volume Unit">VU</abbr> meters</dfn> are the dinosaurs (1939)
+  <tr><th>VU meters</th>
+  <td><dfn><abbr title="Volume Unit">VU</abbr> meters</dfn> are the dinosaurs (1939)
   amongst the meters. They react very slowly, averaging out peaks.
   Their specification is very strict (300ms rise-time, 1&ndash;1.5% overshoot,
   flat frequency response). Ardour's VU meter adheres to that spec, but for
   visual consistency it is displayed as a bar-graph rather than needle-style
   (more below).
-  </dd>
-</dl>
+  </td></tr>
+</table>
 
 <h2>Ardour Specifics</h2>
 
-<img class="right" src="/images/mixer-meter-context-menu.png" alt="mixer strip meter context menu" />
+<figure class="right">
+    <img src="/images/mixer-meter-context-menu.png" alt="mixer strip meter context menu">
+    <figcaption>
+      Mixer strip meter context menu
+    </figcaption>
+</figure>
+
 <p>
-  Meters are available in various places in ardour:
+  Meters are available in various places in Ardour:
 </p>
 <ul>
   <li>The mixer window features fixed height meters for each <dfn>channel strip</dfn>.</li>
   They all share the same configuration and color-theme which is available in
   preferences and the theme-manager. Settings for the Peak and RMS+Peak meters
   as well as VU meter standards are found in
-  <kbd class="menu">Edit &gt; Preferences &gt; GUI &gt; Metering</kbd>.
+  <kbd class="menu">Edit &gt; Preferences &gt; Metering</kbd>.
 </p>
+
 <p>
   The type of meter and the <dfn>metering point</dfn> (the place in the signal chain
   where the meter taps the signal) are configurable in the context menu of each meter.
-  Depending on the <kbd class="menu">Edit &gt; Preferences &gt; GUI &gt; Mixer
-  Strip</kbd> settings, the metering point is also accessible via a button in
-  each Mixer strip.
+  Depending on the <kbd class="menu">Edit &gt; Preferences &gt; Mixer</kbd> settings,
+  the metering point is also accessible via a button in each Mixer strip.
 </p>
-<img class="right" src="/images/meter-preferences.png" alt="" />
+
 <p>
   Regardless of meter type and standard the meter display will highlight red if
   the signal on the given channel exceeds the configured peak threshold.
 </p>
 <p>
-  <kbd class="mouse">Left</kbd> on the peak-indicator button resets the
+  <kbd class="mouse">Left</kbd> clicking on the peak-indicator button resets the
   <dfn>peak-hold indicator</dfn> of a single channel.<br>
-  <kbd class="mod1 mouse">Left</kbd> resets a whole <dfn>group</dfn>, and<br/>
-  <kbd class="mod13 mouse">Left</kbd> resets all meters.
+  <kbd class="mod1 mouse">Left</kbd> clicking resets a whole <dfn>group</dfn>, and<br/>
+  <kbd class="mod13 mouse">Left</kbd> clicking resets all meters.
 </p>
 
 <h2>Overview of meter types</h2>
 
+<figure class="left">
+  <img class="mini" src="/images/meter-types-18.png" alt="Bar-graph meters in Ardour">
+  <figcaption>
+    Bar-graph meters in Ardour
+  </figcaption>
+</figure>
+
+<figure class="right">
+  <img class="mini" src="/images/needle-meters-18.png" alt="Needle-style meters as external LV2 plugins">
+  <figcaption>
+    Needle-style meters as external LV2 plugins
+  </figcaption>
+</figure>
+
 <p>
-  The figure on the left shows all available meter-types in Ardour 3.4 when fed with a
+  The figure on the left shows all available meter-types in Ardour when fed with a
   -18&nbsp;dBFS 1&nbsp;kHz sine wave.
 </p>
 
-<img class="right" style="max-width:45%;height:400px;" src="/images/needle-meters-18.png"
-alt="Needle-style meters as external LV2 plugins" />
-<img style="max-width:45%; height:400px" src="/images/meter-types-18.png"
-alt="Bar-graph meters in Ardour" />
-
 <p>
-  Due to layout concerns and consistent look&amp;feel all meters available in
+  Due to layout concerns and consistent look and feel all meters available in
   Ardour itself are bar-graph type meters. Corresponding needle-style
   meters&mdash;which take up more visual screen space&mdash;are available as
   LV2 plugins (see image on the right):
   <a href="https://github.com/x42/meters.lv2/">meters.lv2</a>.
 </p>
-