--- layout: default title: OSC: Using the Setup Dialog ---

Starting with Ardour 5.1 OSC has a graphic setup dialog. This dialog can be accessed from Preferences->Control Surfaces. Select OSC and click on the Show Protocol Settings.

The Ardour OSC dialog has three tabs. The main tab, the Strip Types tab and the Feedback tab.

Many OSC devices get their IP from a DHCP making it difficult to set an IP in Ardour's OSC settings. Therefore, most of the settings are default settings. Values are set and the next OSC surface to send a /set_surface* message to Ardour will use those settings. An OSC surface that has previously sent a message to Ardour will retain the settings it already had. The Clear OSC Devices will reset all device settings. A /refresh message will both reset the device settings as well as set that device to any new settings. The Use of /set_surface will override all settings except Port Mode.

Dialog settings

OSC setup tab

the OSC configuration dialog

Connection:

This field is informational only. It shows where Ardour will receive OSC messages. The system Name and the Port are the most important parts.

Port Mode:

This drop down allows the choice of Auto or Manual outbound port setting. The default Auto port mode, will send OSC messages back to the port messages from that surface are received from. This setting allows two surfaces on the same IP to operate independently. However, there are a number of OSC control surfaces that do not monitor the same port they send from and in fact may change ports they send from as well. Manual allows the outgoing port (the port the surface will receive on, to be manually set. In Manual port mode only one control surface per IP can work. Most phone or tablet OSC controllers like touchOSC or Control need Manual port mode. More than one controller can be used so long as each has it's own IP.

Manual Port:

This is an Entry box for setting the outgoing port when in Manual port mode.

Bank Size:

This sets the default bank size for the next surface to send a /set_surface/* OSC message. Bank size 0 (the default) sets no banking and allows controlling all strips included in strip_types at once.

Gain Mode:

Sets the faders (and sends faders) feedback math to position where a value between 0 and 1 represents the fader position of the same fader in the mixer GUI or dB where the feedback from fader movement will be returned as a dB value. When the Gain Mode is set to position, the /*/name feedback for the channel will show dB values in text while the fader is being adjusted and then return the the name text.

Debug:

For debugging purposes this allows logging either good OSC messages Ardour receives or invalid messages received or none.

Preset:

Ardour now allows the use of preset settings. The default settings used are the settings from the last session or the factory defaults the first time OSC is enabled. As soon as any of these settings are changed, the Preset will change to "User" and the new settings will be save to the osc directory Ardour configuration directory as user.preset. This preset file can be renamed for future use. It is suggested to also change the name value inside to avoid confusion in the preset listing. Ardour will ship with some of it's own presets that go with some popular OSC control and map combinations.

Clear OSC Devices

This button clears operating device profiles so that Ardour will reset all devices settings to use the new defaults from changed settings. a device may still override these new settings with the /set_surface set of commands. The reason for setting defaults settings is that some OSC controllers are not able to send more than one parameter at a time and so having correct defaults allows one "Connect" button rather than 4.

Default Strip Types tab

the Default Strip Types tab

This allows selecting which of Ardour's mixer strips will be available for control. The Factory default is all strips except master, monitor and hidden strips. If it is desired to only see input tracks the others can be deselected. It is also possible to change these settings from the control surface. A set of buttons could select showing only inputs or only buses. If a group is selected in the GUI then showing only selected strips will show only that group. Showing hidden tracks is handy for cases where a groups of tracks that grouped to a bus or controlled by a VCA are hidden, but one of those tracks needs a tweak.

Default Feedback tab

the Default Feedback tab

This allows setting up which controls provide feedback. The Factory default is none. If the controller is unable to receive feedback, this should be left blank. In the case of metering, Metering as a LED strip only works if Metering as a Float is disabled.