]> Shamusworld >> Repos - ardour-manual/blob - include/vbap-panner.html
Fix a typo in manual
[ardour-manual] / include / vbap-panner.html
1
2 <p class="warning">
3   Ardour's VBAP panner is currently in development, and its semantics may
4   change in the near future, possibly affecting your mixes. Please do not
5   rely on it for important production work while the dust settles.<br/>
6   The Panner only works in fixed static mode, it does not support
7   automation playback.
8 </p>
9 <p>
10   <dfn><abbr title="Vector-base Amplitude Panning">VBAP</abbr></dfn>
11   is a versatile and straightforward method to pan a source around over an
12   arbitrary number of speakers on a horizontal polygon or a 3D surface,
13   even if the speaker layout is highly irregular.
14 </p>
15
16 <h2>Basic concepts</h2>
17 <p>
18   VBAP was developed by Ville Pulkki at Aalto University, Helsinki, in 2001.
19   It works by distributing the signal to the speakers nearest to the desired
20   direction with appropriate weightings, aiming to create a maximally sharp
21   phantom source by using as few speakers as possible:
22 </p>
23 <ul>
24   <li>one speaker, if the desired direction coincides with a speaker
25   location,</li>
26   <li>two speakers, if the desired direction is on the line between two
27   speakers,</li>
28   <li>and three speakers in the general 3D case.</li>
29 </ul>
30 <p>
31   Thus, if you move the panner onto a speaker, you can be sure that only
32   this speaker will get any signal. This is handy when you need precise
33   1:1 routing.<br>
34   The drawback of VBAP is that a moving source will constantly change its
35   apparent sharpness, as it transitions between the three states mentioned
36   above.
37 </p>
38 <p>
39   A <dfn>horizontal</dfn> VBAP panner has one parameter, the <dfn>azimuth
40   angle</dfn>. A <dfn>full-sphere</dfn> panner offers an additional
41   <dfn>elevation angle</dfn> control.
42 </p>
43 <p class="note">
44   More elaborate implementations of VBAP also include a
45   <dfn>spread</dfn> parameter, which  will distribute the signal over a
46   greater number of speakers in order to maintain constant (but no longer
47   maximal) sharpness, regardless of position. Ardour's VBAP panner does not
48   currently include this feature.
49 </p>
50
51 <h2>Speaker layout</h2>
52 <p>
53   Each VBAP panner is specific to its <dfn>speaker layout</dfn>&mdash;the
54   panner has
55   to "know" about the precise location of all the speakers. A complete VBAP
56   implementation must therefore include the possibility to define this
57   layout.
58 </p>
59 <a href="/images/VBAP-panner-5.png"><img src="/images/VBAP-panner-5.png" class="right" style="width:150px;" alt="The VBAP panner with 5 outputs"></a>
60 <p>
61   Ardour currently uses a simplified approach: if a track or bus has more
62   than two output channels (which implies stereo), it assumes that you
63   have N speakers distributed in a regular N-gon. That means that for
64   irregular layouts such as 5.1 or 7.1, the direction you dial in will
65   differ a bit from the actual auditory result, but you can still achieve
66   any desired spatialisation.
67 </p>
68 <h3>Experimental 3D VBAP</h3>
69 <a href="/images/VBAP-panner-10.png"><img src="/images/VBAP-panner-10.png" class="right" style="width:150px;" alt="The VBAP panner with 10 outputs, in experimental 3D mode"></a>
70 <p>
71   For tracks with 10 outputs, Ardour will currently assume a 3-dimensional
72   speaker layout corresponding to Auro-3D 10.1, which is a horizontal 5.1
73   system, four elevated speakers above L, R, Ls, and Rs, and an additional
74   "voice-of-god" speaker at the zenith.
75 </p>
76
77 <h2>N:M panning</h2>
78 <a href="/images/VBAP-panner-4in5.png"><img src="/images/VBAP-panner-4in5.png" class="right" style="width:150px;" alt="The VBAP panner in 4 in, 5 out mode"></a>
79 <p>
80   For tracks and busses with more than one input, Ardour will (for now) assume that
81   you wish to distribute the inputs symmetrically along the latitude around
82   the panner direction. The width parameter controls the opening angle of