2 <p>
3   Starting with Ardour 5.1 OSC has a graphic setup dialog. This dialog
4   can be accessed from Preferences->Control Surfaces. Select OSC and
5   click on the Show Protocol Settings.
6 </p>
7 <p>
8   The Ardour OSC dialog has three tabs. The main tab, the Strip Types
9   tab and the Feedback tab.
10 </p>
11 <p>
12   Many OSC devices get their IP from a DHCP making it difficult to set
13   an IP in Ardour's OSC settings. Therefore, most of the settings are
14   <em>default</em> settings. Values are set and the next OSC surface to
15   send an OSC message to Ardour will use those settings. An OSC
16   surface that has previously sent a message to Ardour will retain the
17   settings it already had. Any change to a setting will reset all
18   device settings. A <em>/refresh</em> message will set that device to
19   any new settings. The use of <em>/set_surface</em> will override all
20   settings except <em>Port Mode</em>. <em>Port Mode</em> affects all
21   connected surfaces and so all surfaces must use either the set manual
22   port or send OSC messages from the same port they expect to receive
23   feedback on.
24 </p>
25 <h2>Dialog settings</h2>
26 <h3>OSC setup tab</h3>
27 <p>
28 <img alt="the OSC configuration dialog"
29      src="/images/osc-dialog.png">
30 </p>
31 <h4>Connection:</h4>
32 <p>
33   This field is informational only. It shows where Ardour will receive
34   OSC messages. The system Name and the Port are the most important parts.
35   Normally, Ardour will use 3819 as its server port. However, if some
36   other server is already using this port, Ardour will try to use the next
37   port up and will keep trying up to 10 ports up.
38 </p>
39 <h4>Port Mode:</h4>
40 <p>
41 <img alt="Port Mode Dropdown"
42      src="/images/osc-portmode.png">
43 </p>
44 <p>
45   This drop down allows the choice of Auto or Manual outbound port
46   setting. The Auto port mode, will send OSC messages back to
47   the port messages from that surface are received from. This setting
48   allows two surfaces on the same IP to operate independently. However,
49   there are a number of OSC control surfaces that do not monitor the
50   same port they send from and in fact may change ports they send from
51   as well. Manual allows the outgoing port, the port the surface will
52   receive on, to be manually set. In Manual port mode only one control
53   surface per IP can work. Most phone or tablet OSC controllers like
54   touchOSC or Control need Manual port mode. More than one controller
55   can be used so long as each has it's own IP.
56 </p>
57 <h4>Manual Port:</h4>
58 <p>
59   This is an Entry box for setting the outgoing port when in
60   Manual port mode.
61 </p>
62 <h4>Bank Size:</h4>
63 <p>
64   This sets the default bank size for the next surface to send a
65   <em>/set_surface/*</em> OSC message. Bank size 0 (the default) sets
66   no banking and allows controlling all strips included in strip_types
67   at once. The entry area will be bright blue for a port that is not
68   valid (ports below 1024 or 3819).
69 </p>
70 <h4>Send Page Size:</h4>
71 <p>
72         This allows setting the size of pages for sends. In the case there are
73         more sends than controls. A size of 0 is the same as no paging and
74         all sends are directly controllable.
75 </p>
76 <h4>Plugin Page Size:</h4>
77 <p>
78         This allows setting the size of pages for plugin controls. Some
79         plugins have hundreds of controls and so it may be necessary to page
80         the plugin controls to a limited number of physical controls. A size
81         of 0 is the same as no paging and all plugin controls are directly
82         controllable.
83 </p>
84 <h4>Gain Mode:</h4>
85 <p>
86 <img alt="Gain Mode Dropdown"
87      src="/images/osc-gainmode.png">
88 </p>
89 <p>
90   Sets the faders (and sends faders) feedback math to position where a
91   value between 0 and 1 represents the fader position of the same fader
92   in the mixer GUI or dB where the feedback from fader movement will be
93   returned as a dB value. When the Gain Mode is set to position, the
94   /*/name feedback for the channel will show dB values in text while the
95   fader is being adjusted and then return the name text.
96 </p>
97 <h4>Debug:</h4>
98 <p>
99 <img alt="Debug Mode Dropdown"
100      src="/images/osc-debug.png">
101 </p>
102 <p>
103   For debugging purposes this allows logging either all OSC messages
104   Ardour receives or invalid messages received or none.
105 </p>
106 <h4>Preset:</h4>
107 <p>
108 <img alt="Preset Loader"
109      src="/images/osc-preset.png">
110 </p>
111 <p>
112   Ardour now allows the use of preset settings. The default settings
113   used are the settings from the last session or the factory defaults
114   the first time OSC is enabled. As soon as any of these settings are
115   changed, the Preset will change to "User" and the new settings will be
116   save to the osc directory in the
117   <a href="@@files-and-directories-ardour-knows-about">Ardour configuration directory</a> as
118   <em>user.preset</em>. This preset file can be renamed for future use.
119   It is suggested to also change the name value inside to avoid confusion
120   in the preset listing. Ardour will ship with some of it's own presets
121   that go with some popular OSC control and map combinations.
122 </p>
123 <h4>Clear OSC Devices</h4>
124 <p class="note">
125         This button has been removed after Ardour 5.10. Instead this action
126         is triggered by any change in the settings.
127 </p>
128 <p>
129   This button clears operating device profiles so that Ardour will reset
130   all devices settings to use the new defaults from changed settings. a
131   device may still override these new settings with the /set_surface set
132   of commands. The reason for setting defaults settings is that some OSC
133   controllers are not able to send more than one parameter at a time and
134   so having correct defaults allows one "Connect" button rather than 4.
135 </p>
136 <h3>Default Strip Types tab</h3>
137 <p>
138 <img alt="the Default Strip Types tab"
139      src="/images/osc-strip-types.png">
140 </p>
141 <p>
142   This allows selecting which of Ardour's mixer strips will be available
143   for control. The Factory default is all strips except master, monitor
144   and hidden strips. If it is desired to only see input tracks the
145   others can be deselected. It is also possible to change these settings
146   from the control surface. A set of buttons could select showing only
147   inputs or only busses. If a group is selected in the GUI then showing
148   only selected strips will show only that group. Showing hidden tracks
149   is handy for cases where a groups of tracks that grouped to a bus or
150   controlled by a VCA are hidden, but one of those tracks needs a tweak.
151 </p>
152 <h3>Default Feedback tab</h3>
153 <p>
154 <img alt="the Default Feedback tab"
155      src="/images/osc-feedbackdefault.png">
156 </p>
157 <p>
158   This allows setting up which controls provide feedback. The Factory
159   default is none. If the controller is unable to receive feedback, this
160   should be left blank. In the case of metering, Metering as a LED strip
161   only works if Metering as a Float is disabled.
162 </p>