2 <p>
3   Starting with Ardour 5.1 OSC has a graphic setup dialog. This dialog
4   can be accessed from Preferences->Control Surfaces. Select OSC and
5   click on the Show Protocol Settings.
6 </p>
7 <p>
8   The Ardour OSC dialog has three tabs. The main tab, the Strip Types
9   tab and the Feedback tab.
10 </p>
11 <p>
12   Many OSC devices get their IP from a DHCP making it difficult to set
13   an IP in Ardour's OSC settings. Therefore, most of the settings are
14   <em>default</em> settings. Values are set and the next OSC surface to
15   send an OSC message to Ardour will use those settings. Any change to a
16   setting will reset all
17   device settings. The use of <em>/set_surface</em> will override all
18   settings except <em>Port Mode</em>. <em>Port Mode</em> affects all
19   connected surfaces and so all surfaces must use either the set manual
20   port or send OSC messages from the same port they expect to receive
21   feedback on.
22 </p>
23 <h2>Dialog settings</h2>
24 <h3>OSC setup tab</h3>
25
26 <figure>
27         <img alt="The OSC configuration dialog" src="/images/osc-dialog.png">
28         <figcaption>
29                 The OSC configuration dialog
30         </figcaption>
31 </figure>
32
33 <h4>Connection:</h4>
34 <p>
35   This field is informational only. It shows where Ardour will receive
36   OSC messages. The system Name and the Port are the most important parts.
37   Normally, Ardour will use 3819 as its server port. However, if some
38   other server is already using this port, Ardour will try to use the next
39   port up and will keep trying up to 10 ports up.
40 </p>
41 <h4>Port Mode:</h4>
42
43 <figure>
44         <img alt="Port Mode Dropdown" src="/images/osc-portmode.png">
45         <figcaption>
46                 Port Mode Dropdown
47         </figcaption>
48 </figure>
49
50 <p>
51   This drop down allows the choice of Auto or Manual outbound port
52   setting. The Auto port mode, will send OSC messages back to
53   the port messages from that surface are received from. This setting
54   allows two surfaces on the same IP to operate independently. However,
55   there are a number of OSC control surfaces that do not monitor the
56   same port they send from and in fact may change ports they send from
57   as well. Manual allows the outgoing port, the port the surface will
58   receive on, to be manually set. In Manual port mode only one control
59   surface per IP can work. Most phone or tablet OSC controllers like
60   touchOSC or Control need Manual port mode. More than one controller
61   can be used so long as each has it's own IP.
62 </p>
63 <h4>Manual Port:</h4>
64 <p>
65   This is an Entry box for setting the outgoing port when in
66   Manual port mode.
67 </p>
68 <h4>Bank Size:</h4>
69 <p>
70   This sets the default bank size for the next surface to send a
71   <em>/set_surface/*</em> OSC message. Bank size 0 (the default) sets
72   no banking and allows controlling all strips included in strip_types
73   at once. The entry area will be bright blue for a port that is not
74   valid (ports below 1024 or 3819).
75 </p>
76 <h4>Send Page Size:</h4>
77 <p>
78         This allows setting the size of pages for sends. In the case there are
79         more sends than controls. A size of 0 is the same as no paging and
80         all sends are directly controllable.
81 </p>
82 <h4>Plugin Page Size:</h4>
83 <p>
84         This allows setting the size of pages for plugin controls. Some
85         plugins have hundreds of controls and so it may be necessary to page
86         the plugin controls to a limited number of physical controls. A size
87         of 0 is the same as no paging and all plugin controls are directly
88         controllable.
89 </p>
90 <h4>Gain Mode:</h4>
91
92 <figure>
93         <img alt="Gain Mode Dropdown" src="/images/osc-gainmode.png">
94         <figcaption>
95                 Gain Mode Dropdown
96         </figcaption>
97 </figure>
98
99 <p>
100   Sets the faders (and sends faders) feedback math to position where a
101   value between 0 and 1 represents the fader position of the same fader
102   in the mixer GUI or dB where the feedback from fader movement will be
103   returned as a dB value. When the Gain Mode is set to position, there
104   are also options to send the gain in dB either to the channel name,
105   /*/name feedback for the channel will show dB values in text while the
106   fader is being adjusted and then return the name text. It can also be
107   set to send both position and gain or just position.
108 </p>
109 <h4>Debug:</h4>
110
111 <figure>
112         <img alt="Debug Mode Dropdown" src="/images/osc-debug.png">
113         <figcaption>
114                 Debug Mode Dropdown
115         </figcaption>
116 </figure>
117
118 <p>
119   For debugging purposes this allows logging either all OSC messages
120   Ardour receives or invalid messages received or none. The last option:
121   <kbd class="menu">Print surface information to Log window</kbd> prints
122   the internal information that Ardour uses to create feedback for all
123   surfaces Ardour knows about.
124 </p>
125 <h4>Preset:</h4>
126
127 <figure>
128         <img alt="Preset Loader" src="/images/osc-preset.png">
129         <figcaption>
130                 Preset Loader
131         </figcaption>
132 </figure>
133
134 <p>
135   Ardour now allows the use of preset settings. The default settings
136   used are the settings from the last session or the factory defaults
137   the first time OSC is enabled. As soon as any of these settings are
138   changed, the Preset will change to "User" and the new settings will be
139   save to the osc directory in the
140   <a href="@@files-and-directories-ardour-knows-about">Ardour configuration directory</a> as
141   <em>user.preset</em>. This preset file can be renamed for future use.
142   It is suggested to also change the name value inside to avoid confusion
143   in the preset listing. Ardour will ship with some of it's own presets
144   that go with some popular OSC control and map combinations.
145 </p>
146 <h4>Clear OSC Devices</h4>
147 <p class="note">
148         This button has been removed after Ardour 5.10. Instead this action
149         is triggered by any change in the settings.
150 </p>
151 <p>
152   This button clears operating device profiles so that Ardour will reset
153   all devices settings to use the new defaults from changed settings. a
154   device may still override these new settings with the /set_surface set
155   of commands. The reason for setting defaults settings is that some OSC
156   controllers are not able to send more than one parameter at a time and
157   so having correct defaults allows one "Connect" button rather than 4.
158 </p>
159 <h3>Default Strip Types tab</h3>
160
161 <figure>
162         <img alt="The Default Strip Types tab" src="/images/osc-strip-types.png">
163         <figcaption>
164                 The Default Strip Types tab
165         </figcaption>
166 </figure>
167
168 <p>
169   This allows selecting which of Ardour's mixer strips will be available
170   for control. The Factory default is all strips except master, monitor
171   and hidden strips. If it is desired to only see input tracks the
172   others can be deselected. It is also possible to change these settings
173   from the control surface. A set of buttons could select showing only
174   inputs or only busses. If a group is selected in the GUI then showing
175   only selected strips will show only that group. Showing hidden tracks
176   is handy for cases where a groups of tracks that grouped to a bus or
177   controlled by a VCA are hidden, but one of those tracks needs a tweak.
178 </p>
179 <h3>Default Feedback tab</h3>
180
181 <figure>
182         <img alt="The Default Feedback tab" src="/images/osc-feedbackdefault.png">
183         <figcaption>
184                 The Default Feedback tab
185         </figcaption>
186 </figure>
187
188 <p>
189   This allows setting up which controls provide feedback. The Factory
190   default is none. If the controller is unable to receive feedback, this
191   should be left blank. In the case of metering, Metering as a LED strip
192   only works if Metering as a Float is disabled.
193 </p>
194